How to set the datalogger add-on.
Helpful articles:How to get Add-On Codes - Krypton® DIS and Activate Add-Ons - Krypton® DIS
Note: The symbols DATALOG and STATUS are shown only if the add-on datalog has been activated.
Always use an empty SD-Card or a SD-Card with limited entries in the root folder. The instrument will automatically generate an appropriate directory structure, e.g. Log files saved in the folder LOG.
Steps:
1. Main menu > IN/OUT > MEMORY
2. If the datalogger option is activated, sixth symbols appear> select LOGGER
3. Select either: Log Para or Log Set
- Log Para - Decide which parameters are logged by checking the tick boxes
- Log Set - Define interval and log mode and view the status
Log Set (Settings):
- Mode - You can start or stop the data logger in this menu
- Interval - defines the time between subsequent datalogs. You can enter an interval of 1 second up to 24 hours
Example: 01:02:03 means that each 1 hour, 2 minutes and 3 second the values are logged.
Note: Never remove the SD card while the logging is running! Always set the mode to OFF (not stop!) before removing the card. Otherwise data loss might occur, and an error message will appear. Always use a card with sufficient storage space, even with ring mode, otherwise the logging will not start.