Skip to Main Content

What is ASR®?

Overview

This article explains the technical function of ASR® (Automatic Sensor Cleaning) and summarizes how the electrochemical cleaning cycle reduces sensor fouling in continuous operation.

ASR® is designed to decrease manual cleaning effort and support stable measurement performance between maintenance intervals.


Operating Principle

During an ASR® cleaning cycle, water is electrolyzed at the sensor surface:

H2O → O2 + H2

The generated gases act directly at the interface where deposits form and create a multi-layer cleaning effect.


Cleaning Mechanism

  • Hydrogen/oxygen bubble formation creates local shear forces that help detach adhered coatings.
  • Oxygen supports oxidation of organic contamination layers.
  • Hydrogen supports reduction of oxide-based deposits (for example iron and manganese compounds).
  • The combined action helps weaken and remove mixed fouling layers, including biofilm-like structures.

Process Characteristics

  • Generated gas volumes are small and remain within normal process operation limits.
  • After the cleaning pulse, gases recombine quickly to water.
  • No external mechanical cleaning step is required during the ASR® cycle.
  • Effectiveness depends on water composition, fouling type, and configured cleaning frequency.

Operational Notes

  • Set cleaning intervals according to observed fouling tendency and process stability.
  • After parameter changes, verify trend stability and sensor response under normal flow conditions.
  • If drift persists, check sample quality, flow conditions, and sensor condition before increasing cleaning frequency further.

Video Reference

Technical overview: ASR® technology video